				Acquisition
				
					Sample Rate: Real-Time: Sample: 1GS/sAcquisition Modes
				
					Normal: Normaldata onlyPeak Detect: High-frequency and randon glith captureAverage:Wavefom Average, selectable 4,8,16,32,64,128Inputs:
				
					Inputs Coupling: AC, DC, GNDInputs Impendance: 1MΩ±2%‖20pF±3pFProbe Attenuation: 1X, 10XSupported Probe Attenuation Factor: 1X, 10X, 100X, 1000XMaximum Input Voltage: CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×); Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.Horizontal System:
				
					Sample Rate Range: 500MS/s--1GS/sWaveform Interpolation: (sin x)/xRecord Length: 40KSEC/DIV Range: 2ns/div to 40s/divSample Rate and Delay Time Accuracy: ±50ppm(at over any ≥1ms time interval)Position range: 2ns/div to 10ns/div;  (-4div x s/div) to 20ms;Delta Time Measurement Accuracy (Full Bandwidth): Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);Sample interval = s/div ÷ 200Vertical System:
				
					Vertical Resolution: 8-bit resolution, all channel sampled simultaneouslyPosition Range: 2mV/div to 10V/divBandwidth: 200MHzRise Time at BNC( typical): 1.8nsAnalog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled: 2mV/div to 20mV/div, ±400mV;  50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V; 5V/div, ±50VMath: +, -, *, /, FFTFFT: Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample pointBandwidth Limit: 20MHzLow Frequency Response (-3db): ≤10Hz at BNCDC Gain Accuracy: ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/divDC Measurement Accuracy, Average Acquisition Mode: When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability, Average Acquisition Mode: Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditionsTrigger System
				
					Trigger Types: Edge, Video, Pulse, Slope, Over time, AlternativeTrigger Source: CH1, CH2, EXT, EXT/5, AC LineTrigger Modes: Auto, Normal, SingleCoupling Type: DC, AC, Noise Reject, HF Reject, LF RejectTrigger Sensitivity (Edge Trigger Type): DC(CH1,CH2):1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
 DC(EXT):
 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
 DC(EXT/5):
 1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
 AC: Attenuates signals below 10Hz;
 HF Reject: Attenuates signals above 80kHz
 LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range: CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6VTrigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns: CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV);Set Level to 50%(typical): Operates with input signals ≥50HzVideo Trigger
				
					Video Trigger Type: CH1, CH2: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2VSignal Formats and Field Rates, Video Trigger Type: Supports NTSC, PAL and SECAM broadcast systems for any field or any lineHoldoff Range: 100ns ~ 10sPulse Width Trigger
				
					Pulse Width Trigger Mode: Trigger when (< , >, = , or ≠); Positive pulse or Negative pulsePulse Width Trigger Point: Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.Pulse with range: 20ns ~ 10sSlope Trigger
				
					Slope Trigger Mode: Trigger when (< , > , = , or ≠ ); Positive slope or Negative slopeSlope Trigger Point: Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.Less than: The oscilloscope triggers when the waveform slope is less than the set slope.Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.Time range: 20ns ~ 10sOvertime Trigger
				
					Over Time Mode: Rising edge or Falling edgeTime range: 20ns ~ 10sAlternative Trigger
				
					Trigger on CH1: Internal Trigger: Edge, Pulse Width, Video, SlopeTrigger on CH2: Internal Trigger: Edge, Pulse Width, Video, SlopeTrigger Frequency Counter
				
					Readout Resolution: 6 digitsAccuracy (typical): ±30ppm (including all frequency reference errors and ±1 count errors)Frequency Range: AC coupled, from 4Hz minimum to rated bandwidthSignal Source: Pulse Width or Edge Trigger modes: all available trigger sources.The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time. Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity. Video Trigger mode: The Frequency Counter does not work.
Measure
				
					Cursor Measurement: Voltage difference between cursors: △V. Time difference between cursors: △T. Reciprocal of △T in Hertz (1/ΔT)Auto Measuerment: Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF.Display
				
					Display Type: 7 inch 64K color TFT (diagonal liquid crystal)Display Resolution: 800 horizontal by 480 vertical pixelsDisplay Contrast: Adjustable (16 gears) with the progress barProbe Compensator Output
				
					Output Voltage( typical): About 5Vpp into ≥1MΩ loadFrequency(typical): 1kHzPower supply
				
					Supply Voltage: 100-120VACRMS(±10%), 45Hz to 440Hz, CAT. 120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡPower Consumption: <30WFuse: 2A, T rating, 250VEnvironmental
				
					Temperature: Operating: 32°F to 122°F (0°C to 50°C); Nonoperating: -40°F to 159.8°F (-40°C to +71°C)Cooling Method: ConvectionHumidity: +104°F or below (+40°C or below): ≤90% relative humidity; 106°F to 122°F (+41°C to 50°C): ≤60% relative humidityAltitude: Operating: Below 3,000m (10,000 feet); Nonoperaring: Below 15,000m(50,000 feet)Mechanical
				
					Size: Length 385mm, Width 200mm, Height 245mmWeight: 3.5KG(with Packing);  2.08KG(without Packing) |